AS1895C
(R) Coupling Assembly, V-Retainer, High Pressure High Temperature, Pneumatic Tube
(R) Coupling Assembly, V-Retainer, High Pressure High Temperature, Pneumatic Tube
2007-08-01
有效
【范围】 1.1 This SAE Aerospace Standard establishes the requirements for a V-retainer coupling, flanges, and seal suitable for joining high pressure and high temperature ducting in aircraft bleed air systems. The rigid coupling joint assembly, hereafter referred to as “the joint”, shall operate within the temperature range of -65 to +1200 °F. 1.2 Types: The joint shall be classified into two basic flange profiles: 1.2.1 Type I: Standard Profile - Per MS24563 Figure 2A (1.50 to 7.50 in duct size) 1.2.2 Type II: Low Profile - Per MS24563 Figure 1 (1.00 to 7.50 in duct size)strRefField
【与前一版的变化】

引用文件/被引文件

Identification Marking Method
Application of V-Band Couplings
T-Bolt and Eyebolt
Standard Practice for Commercial Packaging
Welding
Nut
Screw Threads
Engineering Drawing Practices
Marking for Shipment and Storage
Identification Marking of U.S. Military Property
Test Reports
Fusion Welding for Aerospace Applications
Coupling Flange

相关标准

Performance of Low Pressure Ratio Ejectors for Engine Nacelle Cooling
Fire Test Equipment for Flexible Hose and Tube Assemblies
Flexure Fatigue Strength of Tube Fitting Joints
Safety Criteria for Pneumatic Starting Systems
Hose Assembly Identification Practices
(R) Guide to Temperature Monitoring in Aircraft Gas Turbine Engines
Fittings, Catalog of Flared, Flareless, Pipe Threaded, Port, Hose, and Other Type Tube Standard Connectors
Investigation of PTFE "Melt" Phenomenon for High Pressure Hoses
Oxygen Equipment, Provisioning and Use in High Altitude (to 40,000 ft.) Commercial Transport Aircraft
Aircraft Tube Bending Methods, Techniques and Tooling

包含图表

Joint Control Number
Limit Load at Room T
formula 1
formula 2
formula 3
formula 4
Temperature Correcti
Hydrostatic Proof Pr
Torsional Moment
Qualification Test
Flexure Cycling
Flexure Cycling (Alt
Schematic Diagram of
Schematic Diagram of
Vibration Diagram
Vibration Requiremen
Schematic Diagram of
Coupling Bolt Positi
Schematic Diagram of
Hydrostatic Test
Hydrostatic Proof Pr
Retainer Strength Te
Safety Latch Install
Maximum and Minimum
Safety Latch Inspect

标准反馈