【范围】
|
1.1 Purpose:
This document establishes the minimum requirements for the electrical bonding and grounding of
electric, avionic, armament, communication, and electronic equipment installations for aeronautical
and aerospace applications. The bonding and grounding requirements specified herein are to
ensure that an adequate low resistance return path for electric, avionic, armament, communication
and electronic equipment is achieved which can withstand operating conditions and corrosion. This
is essential for the reduction of coupling of electromagnetic fields into or out of the equipment as well
as for providing electrical stability to control the currents and/or voltages caused by static charges
and discharges and for suppressing the hazardous effects thereof.
1.2 General:
A prerequisite to effective control of electromagnetic interference (EMI) and the hazards of electrical
effects is the establishing of a reference ground plane and the means of providing adequate
connections to it. Making a connection to the ground plane is grounding, and the mechanical
method of providing a low impedance union between conductors is electrical bonding.strRefField
|