【范围】
|
This specification covers the requirements for current limiter type fuses for use in aircraft primary
electrical power systems conforming to MIL-STD-704. These limiters are suitable for use in
MIL-F-5373 fuse holders for operation at -54°C to 125°C.
1.2 Classification:
Limiters shall be as described on the applicable military standard (MS) or specification sheet
(see 6.2).
1.2.1 Style: A style of limiter shall consist of all part numbers in the same current range (0-30A and
35-60A) covered by one military standard or specification sheet. For example: all part numbers
0-30A of MS28937 shall be the same style (see 6.5 for part number example).
1.2.2 Ampere Rating: The ampere rating designator shall be a number specified on each military
standard or specification sheet to indicate the ampere rating.strRefField
|