用户名: 密码: 登 录   个人中心   系统维护   用户注册  联系我们
当前位置 >首页 > 标准信息

全文阅读 全文下载 章节阅读

基本信息

ARP5485A
Endurance Time Tests for Aircraft Deicing/Anti-icing Fluids SAE Type II, III, and IV
Endurance Time Tests for Aircraft Deicing/Anti-icing Fluids SAE Type II, III, and IV
2007-07-01
有效
【范围】 1.1 Purpose The purpose of this SAE Aerospace Recommended Practice (ARP) is to provide the sample selection and endurance time test procedures, for SAE Type II, III, and IV aircraft deicing/anti-icing fluids, required for the generation of endurance time data of acceptable quality for review by the SAE G-12 Holdover Time Subcommittee. 1.2 Examination of Endurance Time Data Periodically, the SAE G-12 Holdover Time Subcommittee examines endurance time test data of SAE Type II, III, and IV aircraft deicing/anti-icing fluids and validates, based on the endurance time data, if such fluids can be used in conjunction with SAE Type II, III, or IV fluid holdover time guidelines. As the SAE G-12 Holdover Time Subcommittee examines endurance time data, it will take into consideration the effects of natural variability of precipitation both in time and space to generate or adjust holdover time guidelines. 1.3 Limits This ARP provides laboratory simulation of freezing fog, freezing drizzle, light freezing rain, snow and rain on cold soaked wing. Other forms of freezing/frozen precipitation are not addressed in this ARP. 1.4 Testing Agent(s) 1.4.1 Independence of the Testing Agents A testing agent shall be independent of the fluid manufacturer and fluid vendor. 1.4.2 Role of the Testing Agent The testing agent shall coordinate activities related to the sample selection procedures (see Section 3). 1.4.3 Sending Samples Fluid samples for testing shall be sent to a testing agent for verification under the sample selection procedures. In turn the testing agent, if the requirements of the applicable sample selection procedure are fulfilled, shall send the samples to the facility/site for endurance time testing. 1.5 Test Facility/Site 1.5.1 Independence of the Test Facility/Site The test facility/site shall be independent of the fluid manufacturer and fluid vendor. 1.5.2 Role of the Test Facility/Site The test facility/site shall be responsible for performing the endurance time tests (see Sections 4 to 11). 1.6 Units The values stated in SI units are to be regarded as the standard. 1.7 Safety While the materials, methods, applications, and processes described or referenced in this ARP may involve the use of hazardous materials, this ARP does not address the hazards that may be involved in such use. It is the sole responsibility of the user to ensure familiarity with the safe and proper use of any hazardous materials and processes and to take necessary precautionary measures to ensure the health and safety of all personnel involved.strRefField
【与前一版的变化】

替代标准

引用文件/被引文件

Aircraft Deicing/Anti-icing Methods
Water Spray and High Humidity Endurance Test Methods for SAE AMS 1424 and SAE AMS 1428 Aircraft Deicing/Anti-icing Fluids
Viscosity Test of Thickened Aircraft Deicing/Anti-icing Fluids
Deicing/Anti-Icing Fluid
Fluid
Aluminum Alloy
-T351 Plate) Solution Heat Treated
Aluminum Alloy
Reagent Water
Quality assurance requirements for measuring equipment

包含图表

EXAMPLES OF WATER DR
REQUIREMENTS FOR FRE
EXAMPLE OF SPRAY NOZ
formula 1
formula 2
ARRANGEMENT OF ICE-C
formula 3
formula 4
FREEZING FOG TEST CO
REQUIREMENTS FOR FRE
ICE-CATCH PANS
FREEZING DRIZZLE TES
EXAMPLE OF A HYDRAUL
REQUIREMENTS FOR LIG
LIGHT FREEZING RAIN
REQUIREMENTS FOR RAI
COLD SOAK BOX
RAIN ON COLD SOAKED
REQUIREMENTS FOR IND
EXAMPLES OF TEST PLA
formula 5
SNOW BOX DISTRIBUTIO
CROSS-SECTION OF SNO
SIDE VIEWS AND CROSS
EXAMPLE OF A SIMULTA
formula 6
formula 7
SNOW TEST CONDITIONS
REQUIREMENTS FOR SNO
TEST STAND AND PLATE
EXAMPLE OF SCHEMATIC
formula 8
CALCULATION OF OUTDO
formula 9
SNOW TEST CONDITIONS
formula 10
TYPES OF FROZEN PREC

标准反馈


  • 问题类型:
    反    馈: