【范围】
|
This SAE Aerospace Standard (AS) contains a sample test plan for AS15531 or MIL-STD-1553B
Remote Terminals (RT) that may serve several different purposes. This document is intended to be
contractually binding when specifically called out in a specification, Statement of Work (SOW), or when
required by a Data Item Description (DID). Any and all contractor changes, alterations, or testing
deviations to this section shall be separately listed for easy review.
1.1 General:
The purpose of these tests is to verify that the Unit Under Test (UUT) responds properly in
accordance with the requirements of the governing standard. The tests are not intended to verify the
mission aspects stated in the equipment specification.
The pass criteria is defined in each test paragraph. If any test fails, record the UUT response to that
test.
1.2 Field of Application:
This general test plan is intended for design verification of remote terminals designed to meet the
requirements of AS15531 and MIL-STD-1553B with Notice 2. Appendix A, B, and C provide cross
references among this test plan, AS15531, and MIL-STD-1553B. For those remote terminals not
required to meet Notice 2, Appendix D and E list the changes in this test plan for MIL-STD-1553B
only and MIL-STD-1553B, Notice 1. The test plan requirements apply to the terminal under test,
when invoked in a specification or statement of work.
When invoked in a specification or statement of work, these requirements apply to the remote
terminal and associated equipment which is developed either alone or as a portion of a system or
subsystem development. The contractor is responsible for invoking all the applicable requirements
of this document on any and all subcontractors he/she may employ.strRefField
|